What was found
DURING C 6 CHECK, THE AFT CARGO PIT FLOOR TRANSITION PANEL, LEFT HAND, WAS FOUND CORRODED BETWEEN STA 727 TO STA 787, LBL 28. REMOVED DAMAGED PANEL AND FABRICATED REPLACEMENT. REPLACEMENT WAS PRIMED, PAINTED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-40-02, 53-60-53, 51-40-05 AND 51-21-02.