What was found
DURING C 6 CHECK, CORROSION WAS FOUND ON THE WEB BETWEEN STA 787 AND 794 AT STR 25R. THE WEB WAS REMOVED IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-40-02. CORROSION WAS FOUND TO BE OUT OF LIMITS IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 53-60-15, FIGURE 101, DETAIL V. A NEW PART WAS FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-30-01. TREATED, PRIMED AND PAINTED IN ACCORDANCE WITH THE REQUIREMENTS OF SOPM 20-41-02. INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-40-02.