What was found
DURING C-4 CHECK, INSPECTION REPORTED AFT CARGO DOOR SILL ATTACH ANGLE AT STA 794.5, RBL 24, CORRODED ON FLANGE. FOUND CORROSION OUT OF LIMITS PER SRM 51-60-15, FIG 106, DETAIL VIII. REPLACED ANGLE PER SRM 51-10-02 AND 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-4 CHECK, INSPECTION REPORTED AFT CARGO DOOR SILL ATTACH ANGLE AT STA 794.5, RBL 24, CORRODED ON FLANGE. FOUND CORROSION OUT OF LIMITS PER SRM 51-60-15, FIG 106, DETAIL VIII. REPLACED ANGLE PER SRM 51-10-02 AND 51-40-02.