What was found
DURING C-4 CHECK, INSPECTION REPORTED AFT GALLEY MOUNT BRACKET CORRODED AT STA. 989, RBL 30. FABRICATED AND INSTALLED REPLACEMENT BRACKET PER EA 53-737-19C, STEP 1, SRM 51-40-02 AND SOPM 20-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-4 CHECK, INSPECTION REPORTED AFT GALLEY MOUNT BRACKET CORRODED AT STA. 989, RBL 30. FABRICATED AND INSTALLED REPLACEMENT BRACKET PER EA 53-737-19C, STEP 1, SRM 51-40-02 AND SOPM 20-41-02.