What was found
DURING C-4 CHECK, INSPECTION REPORTED TRANSITION PANEL IN AFT CARGO COMPARTMENT AT STA 847 - 867, STR 25R, CORRODED. FOUND TO BE OUT OF LIMITS PER SRM 53-60-53 AND 53-60-15. REPLACED PANEL PER SRM 51-40-02, 53-60-15 AND SOPM 21-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-4 CHECK, INSPECTION REPORTED TRANSITION PANEL IN AFT CARGO COMPARTMENT AT STA 847 - 867, STR 25R, CORRODED. FOUND TO BE OUT OF LIMITS PER SRM 53-60-53 AND 53-60-15. REPLACED PANEL PER SRM 51-40-02, 53-60-15 AND SOPM 21-40-02.