DURING C-4 CHECK, INSPECTION REPORTED SHORT INTERCOSTAL AT CENTERLINE BETWEEN STA. 1006 AND STA. 1016 CORRODED. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER EA 53-737-198 AND SOPM 20-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-4 CHECK, INSPECTION REPORTED SHORT INTERCOSTAL AT CENTERLINE BETWEEN STA. 1006 AND STA. 1016 CORRODED. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER EA 53-737-198 AND SOPM 20-41-02.