What was found
DURING C-CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM UPPER CHORD AT STA 312, BL 0. REMOVED DAMAGED UPPER T-CHORD AT STA 312, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 53-10-51 AND 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM UPPER CHORD AT STA 312, BL 0. REMOVED DAMAGED UPPER T-CHORD AT STA 312, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 53-10-51 AND 51-40-02.