What was found
DURING C-CHECK, INSPECTION REPORTED CORROSION ON INTERCOSTAL, STA 328-344, LBL 10, FWD GALLEY. INTERCOSTAL FOUND TO BE OUT OF LIMITS PER SRM 51-10-51. MATERIAL ID FOR NEW INTERCOSTAL WAS BAC 1505-100403 PER BOEING DRAWING 65-48834. COVER PLATE WAS 2024-T3 .090 PER EA B3-53R-10241. INSTALLED COVER PLATE PER EA B3-53R-10241 AND SRM 51-40-02. TREAT PRIMED AND PAINTED PER EA B3-53R-10241 AND MM 51-21-21. INSTALLED PER SRM 51-40-02 AND EA B3-53R-10241.