What was found
DURING C-7 CHECK, INSPECTION REPORTED FWD LAVATORY MOUNT BLOCK AT STA 303, LBL 12, CORRODED. REPLACED LAVATORY MOUNT PER SRM 53-10-15, SRM 53-10-51 AND DRAWING 65C33970.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-7 CHECK, INSPECTION REPORTED FWD LAVATORY MOUNT BLOCK AT STA 303, LBL 12, CORRODED. REPLACED LAVATORY MOUNT PER SRM 53-10-15, SRM 53-10-51 AND DRAWING 65C33970.