What was found
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR BEAM AT STA. 328, RBL 15 TO RBL 35. REMOVED DAMAGED TOP CHORD OF FLOOR BEAM, FABRICATED AND INSTALLED NEW SECTION PER SRM 53-10-51 AND EA B3-53R10393.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FLOOR BEAM AT STA. 328, RBL 15 TO RBL 35. REMOVED DAMAGED TOP CHORD OF FLOOR BEAM, FABRICATED AND INSTALLED NEW SECTION PER SRM 53-10-51 AND EA B3-53R10393.