Service difficulty report · Actuator · Airbus A319111

Difficulty date
March 11, 2005
Submitted
March 14, 2005
Operation
Air carrier
Aircraft
N912FR
Make and model
Airbus A319111
Aircraft serial
1803
Aircraft time
8,967 hours, 4,055 cycles
Part
Actuator
Part number
791C000001
Part serial
Y20780
Condition
Faulty
Location
Te Flap
Part time
8,967 hours, 4,055 cycles
Stage of operation
AP
How discovered
O
Nature of condition
F
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON APPROACH, CREW REPORTED FLAP SYSTEM JAM WHEN FLAPS 2 SELECTED, SLATS EXTENDED TO E CONFIG 3. DECLARED AN EMERGENCY. CHECKED FLAP SYSTEM. FOUND LT WING NR 1 TRANSMISSION TORQUE LIMITER TRIPPED. RESET TORQUE LIMITER. PERFORMED TEST FLIGHT, MADE 3 APPROACHES & SYSTEM TESTED NORMALLY. REMOVED & REINSTALLED PANELS 575DB, 575EB, 575BB AND 573AB. PERFORMED FRICTION CHECK OF NR 4 LT FLAP TRANSMISSION, NR 3 FLAP ACTUATOR, NR 2 FLAP ACTUATOR AND INLINE OFFSET GEARBOX AND CHECKED GOOD. FOUND NR 1 LT AND RT FLAP ACTUATOR CAVITIES FULL OF WATER. REPLACED NR 1 LT AND RT FLAP ACTUATORS PER AMM 27-54-49-PB401 AND CHECKED NORMAL. PERFORMED OPS CHECK OF FLAPS PER AMM 27-54-45-000-003 AND 27-511-49-740-068.