Service difficulty report · Controller · Airbus A319111

Difficulty date
December 12, 2005
Submitted
December 14, 2005
Operation
Air carrier
Aircraft
N924FR
Make and model
Airbus A319111
Aircraft serial
2030
Aircraft time
7,449 hours, 3,413 cycles
Engine
Cfmint CFM565B5
Part
Controller
Condition
Malfunctioned
Location
Bleed Air Sys
Stage of operation
TX
How discovered
O
Nature of condition
B
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BLOCK TURNBACK. FLIGHT CREW REPORTED LOW PRESSURE BOTH ENGINES DURING START WITH FUMES INTO CABIN. REPLACED BMC NR1. LOW BLEED PRESSURE OPS CHECKED GOOD IAW AMM 36-11-34, PAGE 401. FOUND DE-ICE FLUID IN APU AIR INTAKE WHICH WAS CAUSING FUMES. CLEANED APU AIR INTAKE. NO FUMES NOTED IAW AMM 49-16-00-100-003.