What was found
ON SHORT FINAL, A PLASTIC-TYPE BURNING ODOR, WHICH DISSIPATED ON LANDING, NO SMOKE. PERFORMED VISUAL INSP OF CABIN LIVE TV SYSTEM. FOUND SYSTEM OPERATIONAL. PERFORMED TSM TASK 24-00-00-810-823 & TSM TASK 26-15-00-810-804 FOR FUMES & ODORS. NO FAULTS, DAMAGE, OR SOURCE OF SMELL NOTED. INSPECTED NR 1 & 2 PACK BAY AREAS, NO DEFECTS NOTED. REPLACED CABIN RECIRCULATION FILTERS. INSPECTED E&E COMPTS, NO DEFECTS. INSPECTED FWD & AFT CARGO COMPTS, NO DEFECTS. INSPECTED NOSE & MAIN WHEEL WELL, NO DEFECTS. INSPECTED CABIN, LAVATORIES, COCKPIT, AND GALLEYS FOR DEFECTS, NONE NOTED. RAN NR 1 & 2 PACKS WITH NR 1 & 2 ENGINES. NO DEFECTS NOTED. POST FLT REPORT REFLECTS NO FAULTS. RETURNED TO SERVICE.