As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-3 CHECK, INSPECTION REPORTED FWD CARGO PIT FLOOR COVER SHEET CORRODED AROUND SEVERAL HOLES, AFT COVER SHEET NR 131CG. FOUND CORROSION IN FWD PIT AT Y692 TRANSITION SUPPORT PLATE RUNNING FROM FR 28 TO FR 34 AT THE FASTENER HOLES. FABRICATED AND INSTALLED TRANSITION PLATE AND COVER SHEET IAW A319 SRM 51-42-11.