What was found
DURING C4/S1 CHECK, INSPECTION REPORTED SUPPORT FRAME (SHEAR PLATE) BETWEEN FR69 AND FR70, JUST BEHIND FLOORBEAM -Y1292 CORRODED. FOUND SHEAR PLATE TO BE OUT OF LIMITS IAW A319 SRM 53-00-14, FIG. 101. REMOVED SHEAR PLATE IAW A319 SRM 51-42-11, FIG 8. LOCATED AND DRILLED HOLES INTO THE NEW SHEAR PLATE IAW A319 SRM 51-72-11. INSTALLED NEW SHEAR PLATE AND SUPPORT FRAME BETWEEN FR69 AND FR70 IAW A319 SRM 51-42-11, FIG 9, 12, 40 AND 43, TABLE 22 AND 25.