What was found
DURING C4/S1 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM BETWEEN FR68 AND FR69 AT -Y1162. FOUND TO BE OUT LIMITS IAW A319 SRM 53-00-14, FIG. 101. REMOVED AND INSTALLED FLOORBEAM ASSY IAW A319 SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C4/S1 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM BETWEEN FR68 AND FR69 AT -Y1162. FOUND TO BE OUT LIMITS IAW A319 SRM 53-00-14, FIG. 101. REMOVED AND INSTALLED FLOORBEAM ASSY IAW A319 SRM 51-42-11.