What was found
DURING C-3 CHECK, INSPECTION REPORTED HOLES ON JOINT PLATE COMMON TO FLOORBEAM AT -Y1292 BETWEEN FR68 AND FR69 DAMAGED. FABRICATED AND INSTALLED REPLACEMENT JOINT PLATE IAW A318 SRM 53-41-14, FIG 17, AND 51-42-11, STEP 7B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-3 CHECK, INSPECTION REPORTED HOLES ON JOINT PLATE COMMON TO FLOORBEAM AT -Y1292 BETWEEN FR68 AND FR69 DAMAGED. FABRICATED AND INSTALLED REPLACEMENT JOINT PLATE IAW A318 SRM 53-41-14, FIG 17, AND 51-42-11, STEP 7B.