DURING C-3 CHECK, INSPECTION REPORTED FLOORBEAM INBD OF GIRT BAR FLOOR MOUNTS IN L2 DOOR ENTRY WAY CORRODED ON NUT PLATE HOLES (BOTTOM AND TOP). REPLACED FLOORBEAM AT Y1292 BETWEEN FR66 AND FR 68 IAW SRM 51-42-11 AND EA A0-53T-11472.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-3 CHECK, INSPECTION REPORTED FLOORBEAM INBD OF GIRT BAR FLOOR MOUNTS IN L2 DOOR ENTRY WAY CORRODED ON NUT PLATE HOLES (BOTTOM AND TOP). REPLACED FLOORBEAM AT Y1292 BETWEEN FR66 AND FR 68 IAW SRM 51-42-11 AND EA A0-53T-11472.