What was found
DURING C-3 CHECK, INSPECTION REPORTED RT FWD CARGO COMPARTMENT UNDER FLOOR TRANSITION PANEL SUPPORT HAD CORRODED FASTENER HOLE FROM FR 28 TO FR 31. REMOVED AND REPLACED SUPPORT PLATE IAW SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-3 CHECK, INSPECTION REPORTED RT FWD CARGO COMPARTMENT UNDER FLOOR TRANSITION PANEL SUPPORT HAD CORRODED FASTENER HOLE FROM FR 28 TO FR 31. REMOVED AND REPLACED SUPPORT PLATE IAW SRM 51-72-11.