What was found
DURING C-3 CHECK, INSPECTION REPORTED CORRODED FASTENER HOLES UNDER FLOOR SUPPORT IN FWD CARGO COMPARTMENT FROM FR 24 TO FR 28. REMOVED CORROSION IAW SRM 51-74-00. PERFORMED HFEC ON BLENDOUTS OF CORROSION IAW NTM 51-10-08, PART 6. NO CRACKS NOTED. PERFORMED ULTRASOUND IAW NTM 51-10-04, PART 4. ONE LOCATION FWD OF FR C27 OUT OF LIMITS. AREA BLENDED WITH ADJACENT NUTPLATE REMOVED IAW EA #A9-53R-12159. PERFORMED ROTO PROBE INSPECTION OF FASTENER HOLE IAW NTM 51-10-01, PART 6. NO DEFECTS NOTED.