What was found
DURING C-3 CHECK, INSPECTION REPORTED EMERGENCY EXIT LIGHTS CONNECTOR 7260VC8 BROKEN. REMOVED AND REPLACED ELECTRICAL CONNECTOR 7260VC8 IN AFT CABIN EMERGENCY PATH FLOOR LIGHTING SYSTEM IAW AMM 33-51-08 P004, FIG 2. COMPLIED WITH OPERATIONAL TEST OF THE EMERGENCY LIGHTING IN THE CABIN BY THE EMERGENCY EXIT LT SWITCH. NO DEFECTS NOTED. PERFORMED THE OPERATIONAL TEST OF THE EMERGENCY LIGHTING IN THE CABIN BY THE "EMERGENCY EXIT LT" SWITCH IAW 33-51-00-710-008. NO DEFECTS NOTED.