What was found
BIRD STRIKE TO FWD LT SIDE OF FUSELAGE. LT SKIN PANEL DENTED AT FR 4, 11.5" ABOVE STBY STATIC PORT, 2.5" ABOVE SIDE STR 3" BY 4" BY .067. LT SKIN PANEL DENTED AT FR 5 15.5" FROM STBY STATIC PORT, 2.5" ABOVE LT SIDE STR 3.8" BY 2.8"BY .037. INSPECTED AREA PER EA A9-53R-12191. NO ADDITIONAL DAMAGE FOUND. INITIATED TDI 0000682 FOR PERMANENT REPAIR, TO BE DETERMINED BY ENGINEERING WITHIN 50 FLIGHT CYCLES. PERFORMED HFEC AND DVI INSPECTIONS OF AREAS TO BE REPAIRED IAW NTM 51-10-08 AND 51-90-00 NORTEC 2000S AND S/N F9TAB2309C, CAL DUE DATE 08/2008. REWORKED DAMAGED SKIN AREA FR 4 AND FR 5 TO WITHIN LIMITS IAW SRM 51-73-00 FIG 5 AND EA A9-53R-12191. REMOVED SAID FASTENERS IN FR 4 AND FR 5 PER EA A9-53R-12191 AND SRM 51-42-11. ROTO PROBE TESTED FASTENER HOLES IAW NTM 51-10-01, PART 6, PROCEDURE A, NORTEC 2000ST, S/N F9TAB0511C, CAL DUE 10/07. HFEC INSP SURFACE OF REWORKED DENTS IAW NTM 51-10-08, PART 6, NORTEC 2000ST, S/N F9TAB2309C, CAL DUE DATE 08-2008. PERFORMED DVI OF REWORKED AREA IAW NTM 51-90-00, PART 9. NO DEFECTS NOTED. INSTALLED FASTENERS FR 4 AND FR 5 IAW EA A9-53R-12191 AND SRM 51-42-11. PAINTED AREA AS REQUIRED IAW SRM 51-23-11. NO FURTHER ACTION REQUIRED.