What was found
DURING C4/S1 CHECK, INSPECTION REPORTED A SMALL DENT IN THE LT FUSELAGE AT FR 15, STR30, AFT AND ABOVE 02 SERVICE DOOR. REMOVED PAINT FROM AREA IAW SRM 51-75-11 AND BLENDED AREA IAW SRM 51-73-00. DEPTH OF DENT IS .007, SIZE OF DENT IS .4" WIDE BY .5" LONG, 10" FROM CORNER OF DOOR CUTOUT AREA. PERFORMED HFEC ON BLENDED AREA IAW NTM 51-10-08, PART 6, NO CRACKS NOTED. REMOVED TWO FASTENERS, AND PERFORMED ROTOPROBE TEST OF BOTH HOLES IAW NTM 51-10-01, PAGES 601-622, NO FAULTS FOUND. ACCOMPLISHED IAW EA A9-53R-12213.