What was found
DURING C-5 CHECK, INSPECTION REPORTED LIGHT SURFACE CORROSION ON FWD CARGO DOOR SILL WEB. REMOVED NUTPLATE AND REWORKED FOUR SMALL AREAS OF CORROSION IAW SRM 51-42-11 AND 51-74-00. EA NR A9-53R-12316 REQUIRED ACCOMPLISHMENT OF HFEC INSPECTION OF BLENDED AREAS AND ROTOPROBE OF NUTPLATE HOLE TO VERIFY NO DAMAGE PRESENT. PERFORMED HFEC AND ROTOPROBE INSPECTIONS IAW NTM 51-10-08 PART 6, AND 51-10-01 PART 6, PAGES 601-612. NO DEFECTS NOTED.