Service difficulty report · Floor Panel · Airbus A319112
FAA SDR system
- Difficulty date
- December 7, 2007
- Submitted
- December 12, 2007
- Operation
- Air carrier
- Aircraft
- N901FR
- Make and model
- Airbus A319112
- Aircraft serial
- 1488
- Aircraft time
- 22,815 hours, 10,141 cycles
- Part
- Floor Panel
- Condition
- Broken
- Location
- Cabin
- Stage of operation
- IN
- How discovered
- V
- Nature of condition
- O
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-5 CHECK, INSPECTION REPORTED FLOOR PANEL 151PE IN AFT CARGO COMPARTMENT BROKEN INTERNALLY. REMOVED PANEL 151PE IAW SRM 51-42-11. DETERMINED PANEL TO BE BROKEN IN HALF (FULL LENGTH OF PANEL) AND OUT OF LIMITS IAW SRM 53-02-00, FIG 206, SHEET 2. REPLACED FLOOR PANEL 151PE IAW SRM 53-42-14-400-001.