As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON THE DUMMY RAIL SURFACE AND IN NUT CLIP HOLE AT STATION Y503.2 (LT SIDE) JUST FORWARD OF FRAME 16 ON THE IB SIDE OF THE BEAM. DRILLED A NEW DUMMY RAIL IAW THE REQUIREMENTS OF SRM 51-44-11 AND INSTALLED THE DUMMY RAIL IAW THE REQUIREMENTS OF SRM 51-42-11. AFTER THE MAINTENANCE ACTION WAS COMPLETED IT WAS INSPECTED AND FOUND ACCEPTABLE. REFERENCE NON-ROUTINE C035856.