What was found
DURING C3/S1 C CHECK, INSPECTION REPORTED THE AFT CARGO PIT FLOOR PANEL 151BE HAD A PUNCTURE ON ITS UPPER SURFACE. MAINTENANCE REPAIRED THE DAMAGE IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00. FOLLOWING COMPLETION OF THE REPAIR, THE FLOOR PANEL WAS INSPECTED AND FOUND ACCEPTABLE.