As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING THE C3/S1 C CHECK, INSPECTION REPORTED THE AFT CARGO PIT FLOOR PANEL 161CF HAD TWO AREAS OF OUT OF LIMITS DAMAGE ON ITS TOP FACE. MAINTENANCE REPAIRED THE AFFECTED AREAS IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00, PRIMED AND PAINTED THE PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 25-00-00 801. UPON COMPLETION OF THE REPAIR AND PAINTING, THE PANEL WAS INSPECTED AND FOUND ACCEPTABLE.