As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C1 C CHECK, INSPECTION REPORTED AFT CARGO PIT FLOOR PANEL 151ZG WAS DAMAGED BEYOND REPAIRABLE LIMITS. MAINTENANCE REMOVED AND REPLACED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 53-42-14-400-001. FOLLOWING THE REPLACEMENT OF THE FLOOR PANEL, IT WAS INSPECTED AND FOUND ACCEPTABLE. CORRECTED C CHECK FROM C5 TO C1 ON 02/27/08/END/.