What was found
DURING C4/S1 C CHECK, INSPECTION REPORTED THE RIGHT, FORWARD CARGO PIT FLOORBOARD ATTACH POINT AT STRINGER 38 HAD EVIDENCE OF CORROSION AT THE NUT PLATE HOLE LOCATIONS BETWEEN FRAME 28 AND 35. MAINTENANCE REMOVED AND REPLACED THE PROFILE PLATE IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11, PARAGRAPH 6. FOLLOWING COMPLETION OF THE REPLACEMENT, THE PROFILE WAS INSPECTED AND FOUND ACCEPTABLE.