As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C4/S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON THE COVER SHEET OF AFT CARGO PIT FLOOR PANEL 151VG. MAINTENANCE REMOVED THE CORRODED COVER SHEET FROM THE FLOOR PANEL. A REPLACEMENT COVER SHEET WAS FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF EO A9-53E0-20231. THE NEW COVER SHEET WAS INSTALLED AND INSPECTED. UPON COMPLETION OF THE INSPECTION, THE COVERSHEET AND FLOOR PANEL WERE FOUND ACCEPTABLE.