DURING C4 S1 C CHECK INSPECTION REPORTED NUT PLATE CORRODED OUTBOARD OF CENTER FLOORBEAM AFT CARGO PIT C 56 1. MAINTENANCE REMOVED AND REPLACED NEW C 56 PROFILE PLATE IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-42-11 PARAGRAPH 6 AND AIRBUS DRAWING 17D53974965. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE.