As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-CHECK INSP, NOTED FLOORBEAM Y765 RT HAS PITTING CORROSION AT FRAME 68 ON TOP SURFACE. MAINT REMOVED BEAM AND INSTALLED NEW BEAM IAW DRAWING D53472815 AND SRM 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)