As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-CHECK INSP, NOTED AFT PIT FLOOR PANEL 151PE HAS SURFACE CORROSION AROUND ATTACHMENT HOLES AND EDGES. MAINT CLEANED CORROSION, FILLED COUNTER SINK AREA, PREPPED AND PRIMED PANEL 151PE IAW DRAWING 319-53-0001-11 AND AMM 25-00-00-870-001. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)