As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-CHECK INSP, NOTED CORROSION ON FLOOR TRACK AT Y189 FRAME 20. MAINT REMOVED DAMAGED FLOORBEAM Y189 AND INSTALLED NEW FLOORBEAM FROM FRAME 20 TO FRAME 24 IAW SRM 51-42-11 PARAGRAPH 7. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)