What was found
DURING C-CHECK INSP, NOTED UPON CLOSURE OF AFT PIT CORROSION WAS FOUND ON THE SILL WEDGE PANEL 152YG. MAINT INSTALLED A NEW PANEL IAW WORK CARD CP753-25. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSP, NOTED UPON CLOSURE OF AFT PIT CORROSION WAS FOUND ON THE SILL WEDGE PANEL 152YG. MAINT INSTALLED A NEW PANEL IAW WORK CARD CP753-25. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)