What was found
DURING C-CHECK INSP, NOTED AFT CABIN FLOOR PANEL 261HG DAMAGED BEYOND LIMITS. MAINT REMOVED AND REPLACED PANEL 261HG IAW SRM 53-22-12. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSP, NOTED AFT CABIN FLOOR PANEL 261HG DAMAGED BEYOND LIMITS. MAINT REMOVED AND REPLACED PANEL 261HG IAW SRM 53-22-12. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)