DURING C-CHECK INSP, FLOOR PANEL 262FF HAS CORROSION ON SURFACE. MAINT REMOVED AND REPLACED FLOOR PANEL 262FF IAW AMM 53-42-12-400-002. UPON COMPLETION OF THE REPAIR, INSPECTED AND FOUND ACCEPTABLE. (B)