What was found
DURING C-CHECK INSP, NOTED CORROSION AROUND FAR RT NUTCLIP HOLE ON SHEAR PLATE ALONG FRAME 68 BETWEEN Y765 AND Y1292. MAINT REMOVED, FABRICATED AND INSTALLED SERVICEABLE SHEAR PLATE AT FRAME 68 BETWEEN Y765 AND Y1292 IAW DRAWING O53670099, SRM 51-21-11, SRM 51-31-00 AND SRM 53-42-12-420-051B. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)