What was found
DURING C-CHECK INSP NOTED LIGHTNING STRIKE BURN MARK BELOW FWD CARGO DOOR STATION 979 AT STRINGER 38. MAINT REMOVED AND REPLACED BLIND FASTNER WITH HI-LOCK AFTER COLD WORKING HOLE AT STATION 979 STRINGER 38 IAW SRM 53-21-11 FIGURE 210. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)