As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-CHECK, INSP, NOTED THE FLOOR PANEL 251LF NEEDED TOP LAYER OF COMPOSITE REPAIRED IN SEVERAL PLACES. MAINT REPAIRED FLOOR PANEL 251LF IAW SRM 53-02-00 PARAGRAPH 8.A FIGURE 201. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)