What was found
DURING C-CHECK, INSP NOTED THE AFT CARGO PIT FLOOR PANEL, 161CF WAS PUNCTURED. MAINT REPAIRED THE PUNCTURE DAMAGE IN FLOOR PANEL 161CF IAW SRM 53-02-00 FIGURE 204. MAINT PREPARED AND PAINTED THE FLOOR PANEL 161CF IAW THE REQUIREMENTS OF AMM 25-00-00-370-001. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)