What was found
DURING C4/S1 C-CHECK, INSPECTION NOTED CORROSION ON PASSENGER CABIN FLOORBEAM Y765 AT FRAME 66+3 INCHES. MX REMOVED AND REPLACED FLOORBEAM Y765 FROM FRAME 64 TO FRAME 66+6 IAW THE REQUIREMENTS OF A319 SRM 51-72-11, PAGE 1 AND 2. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.