What was found
DURING C3 C-CHECK, INSPECTION NOTED FLOOR PANEL 261FF HAS CORROSION ON THE LOWER SURFACE. MAINTENANCE REPLACED FLOOR PANEL WITH NEW IN ACCORDANCE WITH A319 AMM 53-42-12-400-002.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C3 C-CHECK, INSPECTION NOTED FLOOR PANEL 261FF HAS CORROSION ON THE LOWER SURFACE. MAINTENANCE REPLACED FLOOR PANEL WITH NEW IN ACCORDANCE WITH A319 AMM 53-42-12-400-002.