What was found
DURING C4 C-CHECK, INSP NOTED CORROSION ON FLOOR PANEL PROFILE LOCATED AT FRAME 61 AND STRINGER 38L. MX REMOVED PROFILE, FABRICATED NEW PROFILE AND INSTALLED IAW SRM 53-41-14 ABD 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C4 C-CHECK, INSP NOTED CORROSION ON FLOOR PANEL PROFILE LOCATED AT FRAME 61 AND STRINGER 38L. MX REMOVED PROFILE, FABRICATED NEW PROFILE AND INSTALLED IAW SRM 53-41-14 ABD 51-42-11.