What was found
DURING C6 C-CHECK, INSP NOTED THE FLOORBEAM AT STA Y1162 HAS CORROSION 2 INCHES FWD OF FRAME 68. MX REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-11, 51-44-00 AND 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C6 C-CHECK, INSP NOTED THE FLOORBEAM AT STA Y1162 HAS CORROSION 2 INCHES FWD OF FRAME 68. MX REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-11, 51-44-00 AND 51-42-11.