What was found
REFERENCE NON ROUTINE C068322. DURING DEN C6 C-CHECK, INSPECTION NOTED CORROSION ON THE BOTTOM OF THE L2 DOOR AFT GIRT BAR FITTING BLANKING PLATE. MAINTENANCE REMOVED, FABRICATED AND INSTALLED BLANKING PLATE IAW DRAWING D53480229, SRM 51-31-00, SRM 51-44-11, 51-21-11, 51-75-12.