What was found
DURING C6 C-CHECK, INSPECTION NOTED THE FORWARD CARGO PIT LEFT HAND TRANSITION PANEL PROFILE AT FRAME 34 HAS CORROSION. MAINTENANCE REMOVED, FABRICATED AND INSTALLED THE PROFILE IAW SRM 51-42-11, 51-31-00, 51-26-12, 51-21-11, 51-75-12 AND DRAWING C2D53911628.