What was found
DURING C6 C-CHECK, INSPECTION NOTED CORROSION ON THE FLOOR PANEL ATTACH HOLES, LOCATED A STATION Y1292, BETWEEN FRAMES 66 AND 68. MAINTENANCE REMOVED AND REPLACED THE FLOOR BEAM IAW SRM 53-00-14, SRM 51-42-11 AND SRM 51-44-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C6 C-CHECK, INSPECTION NOTED CORROSION ON THE FLOOR PANEL ATTACH HOLES, LOCATED A STATION Y1292, BETWEEN FRAMES 66 AND 68. MAINTENANCE REMOVED AND REPLACED THE FLOOR BEAM IAW SRM 53-00-14, SRM 51-42-11 AND SRM 51-44-11.