What was found
DURING C4 S1 C CHECK INSPECTION NOTED FORWARD PIT FLOOR PANEL 131CG HAS CORROSION AND TWO BAD INSERTS. MAINTENANCE REMOVED AND REPLACED PANEL IAW AMM 53-22-14-400-001.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C4 S1 C CHECK INSPECTION NOTED FORWARD PIT FLOOR PANEL 131CG HAS CORROSION AND TWO BAD INSERTS. MAINTENANCE REMOVED AND REPLACED PANEL IAW AMM 53-22-14-400-001.